ATM15 - Relative pressure and temperature

Surview

 

Module ATM15:

Description Module for measuring the hydrostatic pressure relatively to the atmospheric air pressure of the site and the water temperature. The hydrostatic pressure is a measurement for the height of the water column, weighing on the sensor.
A/D converter 16 Bit integrating
Interface AquiTronic sensor bus interface

Pressure sensor:

Measuring principle Enclosed  piezo-resistive pressure measuring cell with compensation of temperature
Material Titan
Accuracy 0.1% of final value
Resolution 0.05% of measuring range
Overload up to max. 4-fold measuring range, indication of measuring value up to 1.5 fold measuring range
Compensated
temperature range
0 to +50 °C
Available measuring range 100,200,350,500,700,1000,2000,3500 and 5000 kPa (100 kPa = 1 bar corresponding to approx. 10m water column)

Temperature sensor:

principle of measuring PT1000
Measuring range 0 to +50 °C
Resolution 0.025 °C

General datas:

Housing material V4A high-grade steel, POMŽ
Sealing VitonŽ
Dimensions Total length: 120mm
Length in probe: 105mm
Diameter: 32mm
Weight 250g
Operating temperature -20 to +50 °C

Remarks:

ATM11 measuring module for absolute pressure
ATM10 measuring module for relative pressure
ATM16 Absolute pressure and temperature
CE

AquiLite